Sanitation sprinkler sprinkler pump shaft power consumption is too large Cause and remedies Sanitation sprinkler sprinkler pump under pressure Cause
1. Impede runner or suction line blockage;
2, low power and low speed;
3, the import or export valve is not open enough;
4, the impeller or impeller seal ring wear serious;
Sanitation sprinkler sprinkler pump troubleshooting method
1, eliminate blockages;
2, increase the horsepower to adjust the speed;
3, replace the mouth ring;
4, open enough to import or export valves;
Sanitation sprinkler sprinkler pump shaft power consumption is too high
1, the flow is too large;
2, the pump shaft twists or the impeller collided;
3, the speed is too high;
4, the pump flow channel blocked or stuck;
Sanitation sprinkler sprinkler pump troubleshooting method
1, reduce the flow;
2, appropriately reduced;
3, correction or replacement;
4, eliminate blockages;
Sanitation sprinkler sprinkler water pump has more noise and vibration
1, unstable foot;
2, cavitation phenomenon;
3, bearing wear serious;
4. Sprinklers are blocked or stuck in sprinkler pumps;
5. Sprinklers sprinkle the water pump or there are debris in the import pipeline;
6. Sprinklers sprinkle the water pump and the power machine with different axes;
Sanitation sprinkler sprinkler pump troubleshooting method
1, reinforcement;
2. Adjust working conditions;
3, replace the new bearing;
4, correction or replacement;
5, remove debris;