Pressure checkbench fault phenomenon analysis and processing method:
The pressure calibration table is an ideal high-grade tool list for laboratories, factories, and universities, and can be used to calibrate general pressure gauges, precision pressure gauges, oil pressure gauges, and pressure transmitters as standard gauges for medium and high precision pressure tests. And calibration.
The pressure calibration table has simple structure, high reliability, convenient operation and maintenance, and good sealing performance and is not easy to leak. The pressure adjustment range is large and the lift pressure is stable. Because its structure is open and transparent, it is extremely convenient for users to maintain and maintain.
Pressure calibration station failure phenomenon 1: The host no signal shows possible failures: (1) The detector and the host signal connection disconnected.
(2) The pressure calibration station detects a strong source of interference.
(3) The polishing of the monitoring point is not sufficiently coupled to the detector.
(4) There is a large amount of air bubbles in the internal flow of the pipeline or it is not filled with water, and the inner wall structure of the pipeline is too thick.
(5) The voltage at the pressure calibration station is too low.
Processing method: Check whether the connection between the detector and the host signal is disconnected; change the detection position;
Check whether the detector and the detection point are fully coupled; confirm whether the flow is full;
Increase the transmit voltage; keep the probe and pipe connection surface smooth.
Pressure Calibration Station Failure Symptom 2: Insufficient signal strength possible failure: (1) Pressure calibrator detector moves or does not meet the requirements.
(2) The host power supply is insufficient.
(3) The fouling on the inner wall of the pipeline at the monitoring site is too thick, and the treatment of the outer wall attachments is not complete.
(4) Whether the pipeline is full of water or foreign matter that has scale.
(5) The probe is not installed correctly.
Treatment method: Check the position of the pressure checker detector and the power supply of the main unit, tap the external wall of the pipeline to shake off the scale, and dispose of the attachments on the outer wall again;
Check if the probe is installed properly.
Pressure calibration station failure phenomenon 3: Calculation of abnormal possible failure: (1) Received signal exceeds, ultrasonic signal is too large.
(2) The type of fluid is abnormal in sound velocity, and the abnormality is calculated and calculated.
Treatment method: Reduce the signaling voltage appropriately, change the probe installation method;
Set the exact corresponding sound speed value.
Pressure Calibration Station Failure Symptom 4: Flow is constant, but measurement of instantaneous pressure fluctuations is very likely. Failure: (1) Signal strength fluctuates greatly.
(2) The fluctuation of the fluid itself is measured.
(3) There is a pulsation.
(4) The straight section is not long enough.
Treatment method: Adjust the position of the pressure calibration table probe to increase the signal strength and keep the signal stable. If the fluid itself fluctuates greatly, the position selection is not good. Avoid fluid disturbance components such as pumps or valves; increase the pressure coefficient setting.

Methanol Quick Connector with double seal ring radial seal structure, rubber modified by O - ring, mainly for fluid and the physical, chemical properties of custom, prevent aging, corrosion, swelling; O - ring have intermediate spacer ring separated, two sealing rings of the corresponding event space, the rubber matrix bonding does not occur, the external O-ring using synthetic rubber, enhanced mechanical properties, prevent air aging. Sealing ring and a spacer ring through the outer ring of the elastic bayonet device firmly fixed in the shell, does not produce seal off and shift phenomenon produced. Greatly ensure the safety of the seal.

Methanol quick joint belongs to a fast joint, it can quickly assemble, without the tool. It can save time, reduce the cost, and can realize the characteristics of automatic assembly, it is mainly suitable for automatic production line.

Ethanol & Methanol Quick Connector

Methanol Quick Connector,Fluid Quick Connectors,Ethanol Quick Connector

Linhai Shinyfly Auto Parts Co.,Ltd. , https://www.chinashinyfly.com