4.Overview Infrared thermometers measure body temperature by detecting the infrared energy emitted from the eardrum or forehead. Proper positioning of the sensor ensures quick and accurate results. Normal body temperature varies depending on the measurement site. For example, a normal forehead temperature ranges from 36.1°C to 37.5°C, while an ear temperature typically falls between 35.8°C and 38°C. These differences mean that readings from different sites should not be directly compared. Always inform your doctor about the type of thermometer used and the location where the temperature was taken.  Measurements Forehead temperature 36.1°C to 37.5°C (97°F to 99.5°F) Ear temperature 35.8°C to 38°C (96.4°F to 100.4°F) Oral temperature 35.5°C to 37.5°C (95.9°F to 99.5°F) Rectal temperature 36.6°C to 38°C (97.9°F to 100.4°F) Axillary temperature 34.7°C-37.3°C (94.5°F-99.1°F)  5.Structure The thermometer includes a casing, LCD display, a measuring button, a buzzer, an infrared temperature sensor, and a microprocessor for accurate readings. 6.Operating principle The infrared sensor captures the thermal radiation from the eardrum or skin surface. This energy is then focused through a lens and converted into a temperature reading using thermopiles and measurement circuits. 7.Indications for use This dual-mode infrared thermometer is suitable for measuring human body temperatures. The forehead mode is appropriate for all ages, while the ear mode is recommended for individuals over three months old. 8.Contraindications Do not use this device if the ear is infected or has any discharge. 9.Temperature taking tips 1) It's important to know your normal temperature when you're healthy. Record two readings daily and calculate the average for an accurate baseline. Always take the temperature in the same location, as readings may vary across different areas of the forehead. 2) A child’s normal temperature can range from 97.0°F (36.1°C) to 99.9°F (37.7°C). Note that this device may read 0.5°C (0.9°F) lower than a rectal digital thermometer. 3) External factors like lying on one ear, covering the ears, exposure to extreme temperatures, or recent swimming/bathing can affect readings. Remove the individual from these conditions and wait 20 minutes before measuring. 4) Avoid holding the thermometer too long in your hand before measuring, as it may warm up and affect the result. 5) Ensure both the patient and the thermometer are in a stable room environment for at least 30 minutes before measuring. 6) Clean the forehead area before placing the sensor, and wait 10 minutes after cleaning before taking a reading. 7) Use an alcohol swab to clean the sensor and wait 5 minutes before measuring another person. Wiping the forehead with a warm or cool cloth might influence the reading—wait 10 minutes before measuring. 8) For newborns or children under three years with compromised immune systems, take 3-5 readings in the same location and use the highest one as the result until consistent readings are obtained. 10.Care and cleaning Clean the casing and sensor with an alcohol swab or cotton swab moistened with 70% alcohol. Allow the alcohol to dry completely before taking another measurement. Ensure no liquid enters the internal components. Avoid using abrasive cleaners, thinners, or benzene. Never immerse the device in water or other liquids. Handle the LCD screen carefully to avoid scratches. 11.Warranty and After-Sale Service The device comes with a 12-month warranty from the date of purchase. Batteries, packaging, and damage caused by improper use are not covered under warranty. Exclusions include failures due to unauthorized disassembly, accidental drops during use or transport, or failure to follow the user manual. Impact Mill,Lns Impact Mill,Centrifugal Impact Mill,Lithium Hydroxide Mill Mianyang Liuneng Powder Equipment Co., Ltd , https://www.lnpepowder.com
Features
Quick and accurate readings in just 1 second.
Advanced algorithm for precise temperature calibration.
High accuracy with ±0.2°C precision.
User-friendly one-button operation for easy use.
Tri-color indicator light with fever alarm function.
Stores up to 35 previous measurements for reference.
Multi-functional design supports forehead, ear, room, and object temperature measurements.
Switch between mute and non-mute modes as needed.
Switch between Fahrenheit and Celsius units easily.
Automatic shutdown for energy saving.
Optional features include an ear probe cover and Bluetooth connectivity.
Specifications
Model No.
FC-IR100
Measurement range
Ear & Forehead: 32.0°C-42.9°C (89.6°F-109.2°F)
Object: 0°C-100°C (32°F-212°F)
Measuring accuracy
Ear & Forehead mode:±0.2ºC /±0.4°F
Object mode:±1.0°C/1.8°F
DisplayÂ
LCD backlight
Automatic shutdown
10s±1s
Memory
Stores 35 previous temperature readings.
Fever alarm
Low fever:37.4ºC<=T<=37.9ºC°(99.3°F-100.3°F)
High fever:38ºC<=T<=42.9ºC(100.4°F-109.2°F)
Operational conditions
Temperature: 10ºC-40ºC (50°F-104°F)
Humidity: 15-95%RH, non-condensing
Atmospheric pressure: 86-106 kPa
Battery
2*AAA, can be used for more than 3000 times
Weight
66g(without battery); 81g (with battery)
Product Dimension
39*27.3*160mm
Packing size
46.5*46.5*169mm
Full set weight
113g (including products / bags / instructions/ batteries)
Performance show
CONTACT US
Model NO.: UP-580
Trademark: OEM
Transport Package: OEM Packing
Specification: 39*27.3*160mm
Origin: China
HS Code: 9025199010