Model NO.: 1009
Runner: Cold Runner
Design Software: UG
Installation: Semi Fixed
Certification: ISO
Standard: HASCO
Customized: Customized
Deliver Time: 40-60 Work Days
Mould Life: 0.5-1 Million
Tolerance: ± 0.02mm
Mould Quality Control: Professionla QC
Mould Material: 718
Trademark: Customized
Specification: 1200*1000*520mm
Origin: China
HS Code: 8480710090
Professional Plastic Injection Mould Manufacturer with more than 15 years of experience, specializing in Plastic Injection Mould with Cold &Hot Runner
 


Pipe fitting mould:
Name High Precision Injection Pipe Tee Fitting Mould
Plastic material PVC
Steel of Cavity & Core DIN 1.2316
Steel of Mouldbase S50C. LkM standard^ etc
Nos of Cavity Customized
Hardness of Cavity & Core 48-52HRC
Hardness of Wear Parts 55-60HRC
Core pulling system Motor /oil cylinder/ stripping plate, angel pin^ etc
Mould Accessories DME/HASCO Standard ^
Cooling system In core baffle cooling and in cavity plate chain drilling type cooling
Surface finish Diamond polish,
Molding  life 1.000, 000shots
Runner Cold 
Delivery time 55work days
Packing wooden case
Payment T/T L/C Paypal

Advantage:
1. Specialize in Automotive mold/commodity mold/thin-walled mold/plastic container mold/household electric mold  with more than 15 years of experience.
2. High quality & competitive price & professional skills.
3. In house strict quality control.
4. Fast and on time delivery with decent orders
5. All molds could be produced automatically
 
Offered Service:
1. Mold progress report and tooling schedule will be provided weekly.
2. The first testing sample for buyer's inspection and work out improvement requirements will be provided.
3. Mold testing video, 2D part drawing and 3D mold design before shipment will be provided.

Plastic  injection Mould:
1.Samples/Drawing & Requirement from you
2. Mould design: we will Communicate& Exchange the opinion with you after you place order.
3. Material Purchase: Steel cutting and Mould base tooling.
4. Assembling.
5. Inspection of mould: following and controlling the tooling processing.
6. Mould testing: We will inform you the date. Then will send the sample' s inspection report& injection parameters with the sample to you!
7. Your instruction & confirmation for shipment.
8. Finished mould before packing.
 
If you need any further information, please feel free to contact me.
 
No. Machine name QTY Type Travel itinerary origin pucchased date
1 High speed milling 1 AV1612 1600*1200 Taiwan 09/2014
2 High speed milling 1 H22S150 2200*1500 Taiwan 05/2014
3 High speed milling 1 AV1280 1200*800 Taiwan 09/2014
4 CNC 1 HB-3190 3000*1970 Taiwan 02/2015
5 CNC 1 SVW3217 3200*1700 Taiwan 05/2005
6 CNC 1 HB-2190 2200*1970 Taiwan 07/2008
7 CNC 1 TZ-2520 2500*2000 Taiwan 11/2010
8 CNC 1 VEL-1680 1600*800 Taiwan 05/2005
9 CNC 1 HB-1890 1800*1000 Taiwan 10/2007
10 CNC 1 HB-1580 1500*850 Taiwan 07/2008
11 CNC 1 VEJ1060 1000*600 Taiwan 04/2008
12 Driller 1 ZJ4060 diameter:60 Shenyang 05/2005
13 Driller 3 ZJ3050 diameter:50 Shenyang 08/2008
14 Driller 1 ZJ3040 diameter:40 Shenyang 09/2011
15 Driller 1 DHD2000 2000*1600 Taiwan 04/2012
16 Driller 1 DHD1500 1500*1300 Taiwan 04/2012
17 CNC engraving and milling machine 2 S600B 600*600 Beijing 06/2014
18 CNC engraving and milling machine 2 400GA 400*400 Beijing 06/2014
19 Wire cut 3 (HWC 53S) 500*300*210 Beijing 05/2010


The insulation breakdown accident often occurred in generator. It includes interphases short circuit, inter-turn short circuit and ground fault.

    The interphase short circuit: the generator windings ends will be greatly impacted by electric power and may make the coil end deformed under two-phase or three-phase short circuit and differential protection tripping happening.

   Inter-turn short circuit: Generator outlet blasting, if it continues a long time, the stator copper wire will be melted. When no-load run, the generator three-phase voltage will be imbalance.

   Ground fault: Generator breakdown location is in the linear portion or notch position and stator ground protection act. The insulation resistance value between stator ground and ground is zero or minimum.

   The fundamental reason of generator insulation breakdown is that the stator coil insulation is weak or there is a corona etching in notch in run time. The treatment method is to find the point of breakdown and reworked and reinforced insulation. At the same time, eliminating the corona etching in a maximum extent is important.

III. A large noise or vibration with generator

   The reasons of a large noise or vibration with generator are:

   1. Foundation bolts loose, or STG subsidence. Treatment: fastening bolts. Recalibration concentricity.


   2. Generator rotor and Steam Turbine shaft are misalignment. Treatment: calibration concentricity.


   3. Bearing wall worn or damaged under short oil. Treatment: repaired bearing or replace a new bearing with same model.


   4. There is a friction between the stator and rotor. Treatment: find the friction location and reason, and then eliminate it.


   5. Fan or other fasteners loose. Treatment: Tighten fan and fasteners.


   6. Rotor coil partial short circuit, two points grounding or wiring errors. Treatment: please inspect the insulation of slip ring and the rotor coil to the ground. Or connect to the DC power source and check the voltage drop of each coil, winding direction and wiring method. So we can identify the cause of the malfunction and eliminate them.


  7. Brush is too hard, or the pressure is too large. Treatment: adjust the pressure or replace the same type of brush.


  8. Three-phase current are severe asymmetry. Treatment: please investigate that the three-phase current imbalance is in the allowable range or not. If it is not in the allowable range, please adjust three-phase load or reduce the load.


   9. Stator winding short circuit or ground. Treatment: Find out the fault and repair it.


   10. External fault or lightning strike. Treatment: if the vibration time is too long, please stop the STG and inspect.


Typical

cases:


   This is a 15 MW generator from a Shandong customer. The vibration of generator is reached to 0.12mm in running. After inspection the generator, we found that rotor dynamic AC impedance upheaval 12% in 2400-2700 and the dynamic inter-turn short circuit is serious. It destroys the balance of the magnetic field and causes the electromagnetic force uneven of generator rotor. After removal of the rotor retaining ring and treatment the rotor inter-turns, we start the STG. The vibration is about 0.01mm.


IV. The temperature of a generator is too high.


   Generally the temperature of a generator will be in the allowable value, if the generator running normally and the current, voltage, frequency, power, excitation current and power factor are all within the allowable fluctuation range. If a generator stator, core and other parts temperature are too high, please consider the following cases:


   1. Generator overload operation and exceed the allowable time. Treatment: Please reduce the generator load to the rated load or under rated load as soon as possible.


   2. Three-phase current are serious imbalance. Treatment: please find out the reason of imbalance. If it is the voltage causing, please check if it is the generator inter-turn short circuit. If it is load causing, please adjust the load and make it balance.


   3. The ventilation cooling system of generator is poor. For example, the temperature is too high, the air duct or exhaust duct are blocked, the coil and its ends are serious fouling. Treatment: please reduce the load suitability, improve ventilation, and remove fouling.


   4. The stator winding portion short circuit or ground. Treatment: Find out the short circuit or ground point and repair them, and then eliminate short circuit or ground risks.


   5. Insulation of the stator core may be partially damaged and short circuit, so there is a vortex and overheat. Treatment: please reduce the load suitability. If the generator reduces its efficiency obviously, please repair the generator stator core.


   6. The bearing is short of lubricating oil. The oil number is wrong. The oil quality is bad. The bearing is installed with a wrong way or the bearing is damaged. Treatment: please find out the reason and then replace the oil or clean, adjust or replace bearing.



V. Generator rotor ground


   Symptom: Generator grounding one point or two points grounding light plate light.


   Fault Analysis: Generator rotor winding insulation damage, coil deformity and severe dust and greasy attached in the ends seriously are all leading to the grounding of the generator rotor windings. When the generator rotor winding grounding in one point, there is electrical current pass as the ground does not constitute an electrical circuit.

However, after one point grounded, it is easy of leading another grounding point. If any part in excitation circuit ground, it can form ground fault of two or more points ground. It is very dangerous.

After the failure, the rotor windings are short-circuited. Because of the small winding DC resistance, the excitation current will increase. So the magnetic field of generator is out of balance, and main magnetic flux reduces largely. So the STG will vibrant strongly. Meanwhile the power factor of the generator will be increased significantly and get into leading phase running (absorption of reactive power from the grid).


   The stator field becomes in the frond and the rotor field becomes in the back. It will make the stator current increases. If the watcher notice that there is no excitation varying but the excitation current and stator current suddenly increases, and the excitation voltage and AC voltage are all suddenly drop, and power factor meter indicates increasing or leading phase, it means the generator rotor grounded or inter-turn short circuited. You should shut down the STG and blow-out magnetic. Please inspect the excitation system and rotor windings, and find out the short circuit point and treat it.  



VI. Excitation upgrading and generator test


   Excitation system upgrading, brushless exciter changes into the SCR excitation and make the generator maintenance easily. And it removes the disadvantage of brushless excitation dynamic adjustment slowly. The generator test includes stator insulation resistance test, the absorption ratio test, the iron loss test, leak test, AC and DC voltage withstand test, the rotor high speed balancing and overspeed test, dynamic and static AC impedance test, the generator no-load test, short circuit test, temperature rise test, residual pressure measurement, axis voltage measurement.



Generator Care

Generator Care,Steam Turbine Generator Care,Msw Power Generation,Combined Cycle Generating Unit

Shandong Qingneng Power Co., Ltd. , https://www.steamturbine.be